DESCO PORTABLE ANAESTHESIA APPARATUS (Cat. No. D-AN 1011)
INTRODUCTION
Portable Anaesthesia Apparatus is the outcome of painstaking R & D by our team of dedicated engineers to meet the ever increasing demands of the practising Anaesthesiologist & Small Nursing Homes, where stress has been given to the safety, compactness, easy operation, accessibility and visibility of all components.

FEATURES

A. SAFETY
This Apparatus features an exclusive NITROUS OXIDE LOCK with Audio-Visual Alarm System. The Rotameter ensures protection against singular flow of Nitrous Oxide until a minimum flow of 1 Litre Oxygen is released. Simultaneously, a built-in Audio-Visual Alarm will be activated if the Oxygen flow (even by error) is not released through the Rotameter.

B. CONTROL KNOBS
Colour coded and labelled for easier identification of respective gases. The Control knobs have a characteristic profile to get a tactile feeling upon touch by the Anaesthesiologist. As desirable, Oxygen Control knob is placed before Nitrous Oxide Control knob.

C. ROTAMETER PROTECTION
Nitrous Oxide and Oxygen Rotameter Tubes are protected by a Transparent Shield which can be easily removed for cleaning or servicing.

D. PRECAUTIONARY MEASURE
To eliminate the risk of wrong connection, inlet connections of Nitrous Oxide and Oxygen are of non-interchangeable type. THE APPARATUS The entire Anaesthesia Apparatus is supplied in an exclusive carrying case with the following accessories:

1. Head Assembly fitted on a base plate within a frame having one drawer and provided with:
(A) Oxygen and Nitrous Oxide Rotameter Set.
(B) Ether or Halothane Unit with Glass Bottle.
(C) Emergency Unit-cum-Outlet.
(D Toggle Switch for Audio-Visual Alarm System.

2. Bag Mount
3. Rebreathing Bag (2 Itrs.)
4. Corrugated Tube (Anti-Static)
5. Expiratory Valve
6. Angle Mount for fitting with Expiratory Valve.
7.Catheter Mount for small rubber tube.
8. Face Mask Adult
9. Nitrous Oxide Preset Regulator Pin-Index Type (for Pin-Index Cylinder)
10. Oxygen Preset Regulator (for Bull Nose Cylinder)
11.2 Nos. High Pressure Ribbed Nylon Tubing with End-Fittings for connection to the preset Regulators-one      for Oxygen and the other for Nitrous Oxide.
12. Cylinder Opening Keys (2 nos.)

OPTIONAL
(A) Goldman Vaporiser (Indian) for attachment at the outlet;
(B) T Connector with Non-return valve for using Twin-Cylinder.

Request for quote >>  
 
 
DESCO Anaesthesia Machine (Cat. No. D-AN 1012)
DESCO Major model designed with patient safety device having oxygen failure alarm & N20 cut-off systems. This objectives successfully fulfilling the all day by day essential Anaesthesia needs and requirements of the actual user.

FEATURES

  • 1Oxygen flow- meter (230 mm) long tube rotating bobbin range 100 cc/min to 10.00 Lt.
  • 2Nitrous -Oxide flow meter (230 mm) long tube rotating bobbin range 200 cc/ min. to 12 Lt.
  • Plenum type Ether unit with glass bottle. Halothane unit with glass bottle.
  • Distance piece (for one more vaporizer).
  • Non return cum Blow - off unit.
  • Oxygen failure warning device.
  • Nitrous oxide cut off systems (When oxygen flow fall less then 1.5 Lt.
  • Alarm will be on (This is non- electric alarm, lengthy alarm. You have to close N2O cylinder to stop the alarm.
  • Four regulators with safety valve and non return valve ( two four O2, Two for N2O) Yoke assemblies for O2 &    N2O.
  • fitted with pressure dial (63 mm) to show the pressure of cylinder for O2, N2O.
  • Space for ventilator.
  • Self-sealing valves to start ventilators or start machine through gas pipe line.
  • Change over unit gas outlet cum emergency oxygen unit & change the line open to close circuit.
  • Megill circuit complete with Bag mount, 2 Lt.
  • Re- Breathing bags Corrugated tube , Head bring valve with angle amount, Face mask , catheter mount and tool kit.
  • Top tray at eye level.
  • Table top made of stainless steel.
  • Drawer to keep medicines, Instruments etc.
  • Provision for 10 Lt.
  • capacity cylinder O2 & N2O at the backside.
  • Antistatic wheels with front break.
  • Electro statically powder coated frame.
OPTIONAL
  • Circle absorber.
  • Conversion kit for N2O & O2 ( Regulator to start machine from big cylinders).
  • B.P. Apparatus.
  • Bain Circuit & spares Face mask & Re-breathing bags.
  • Oxygen monitor.
Request for quote >>
 
 
DESCO PREMIUM ANAESTHESIA DELIVERY SYSTEM WITH ORC (Cat. No. D-AN 1013)
INTEFRATED SAFETY FEATURE:
Oxygen Ratio controller (ORC) never allows delivery lof 100% Nitrous Oxide by ensuring delivery of atleast 25% Oxygen concentration to prevent Hypoxia.

FEATURES:

Oxygen Ratio Controller (ORC):
In the ORC a slave valve pneumatically linked to two pressure balancing diaphragms of Oxygen & Nitrous Oxide guarantees a minimum of 25% Oxygen Concentration which can be raised anywhere in the range of 25% to 100% (5%.)
Oxygen Failure Protection Device:

(OFPD):
MEDISYS OFPD works as a true Fail-safe system allowing flow of Nitrous Oxide only in presence of Oxygen at Rotameter level since it locks the flow of Nitrous Oxide in the absence of flow of Oxygen through its Rotameter.

Basal Flow:
When MEDISYS OFPD is in operation as indicated by Audio-Visual Alarm, a separate Pneumatic Circuit is activated to deliver a minimum Oxygen Flow of 200 - 300 ml/min through its Rotameter.

Alarm:
Audio-Visual Alarm is activated if flow of Oxygen falls belowlLPM.

Pneumatic Circuitry:
Completely encased, detachable Pneumatic Circuitry for easy & prompt service check up.

Circle Absorber System:
Twin Canister Circle Absorber System is provided with swivelling facility. Canisters and Inspiratory Valve have quick -fit Taper Fitting with Rubber '0' Rings for Leak proof seal and easy maneuverability. Bag-Mount & APL Valve Assembly have swivel arms for easy accessibility.

Emergency Oxygen:
Emergency Oxygen Flush Button is provided at Table Top level on the front. It is recessed and guarded to avoid accidental pressing.
Flow Range : 35 LPM Calibrated at 60 PSI (5%)

Vaporizers:
The Vaporizers of Ether and Halothane are supplied as standard accessories. Provision for incorporating Vaporizer of user's choice in the Back Bar, Viz. Floutec, Penlon etc. (Optional)

Non-Return cum Pressure Relief Valve:
Blows off excess pressure in the Circuit. Release Pressure: 100 CM H20 (10%.)

Patient Circuit:
a) Standard MagilPs Circuit -01 No.
b) Complete Closed Circuit - 01 No.
c) Face Mask -02 Nos. (Adult & Child)
d) 2 Ltrs. Capacity Rebreathing Bag -2 Nos.

Rotameters:
  • 230mm long accurately calibrated Rotating Bobbin Flowmeters :
  • Oxygen : 100 ml/min to 10 LPM
  • Nitrous Oxide : 200ml/minto12LPM
Ventilator Driving Source:
provided for driving a Ventilator. Operating Pressure: 60 PSI

Construction:
Tubular Rigid Steel Sections: Powder Coated

Shelf for Ventilator:
Sufficient space provided at the top level of Lower Drawer to place MEDISYS Medivent Servo Anaesthetic Ventilator (Ventilator optional).

Drawer:
Sufficient space provided in an extra - large storage drawer to accommodate all accessories.

Table Top:
Guarded Table Top provided with a Stainless Steel Tray (560 mm x 260 mm).

Instrument Tray:
Top Tray provided at eye level for keeping Monitoring Equipments.

Gas Supply Options:
'Central Gas Pipe Line      : 0xygen & Nitrous Oxide with display Gauges.
Pin-Indexed Yokes             : 2 Nos. each for Oxygen & Nitrous Oxide. Each Gas Specific Yoke includes separate Gauge, Regulator and Mounting Hardware.

Dimensions            : Height : 160cm             : Depth : 68cm             : Width : 62cm

Request for quote >>
 
 
DESCO Anaesthesia Machine (Cat. No. D-AN 1014)

SPECIFICATION
1. Two Gases Rotameter Oxygen & Nitrous-Oxide
2. Oxygen Flowmeter range 100 cc/min. to 10 litres/min., Nitrous Oxide Flowmeter range 200cc /min. to 12      litres/min.
3. Standard Fresh Gas Outlet.
4. Change Over System Open Circuit to Close Circuit.
5. Emergency Flush Valve at front Panel connected to incoming O2 supply
6. Goldman type Halothane Vaporizer.
7. Parking space for two additional Vaporizers.
8. Non-return cum Pressure Relief Valve minimize risk of back flow of gases.
9. Blows off valve when pressure exceeds 200cm of water column fitted.
10. Provision to fit Ventilator.
11. Provision to fit Carbon Dioxide Absorber.
12. Extended platform at rear for two 'B' type cylinder.
13. Table top made of Stainless Steel.
14. Top Tray provided at eye lavel for keeping Monitoring Equipments.
15. Maggill's or Bains circuit.
16. Three spacious Drawer on smooth runner.
17. Four Castor Trolley with front two lockable Wheels.
18. Pin Index Yokes two for Oxygen and two for Nitrous Oxide.
19. High-efficiency Regulators for reliability two each for O2 & N2O.

SAFETY FEATURES
* N2O cut off in case failure of Oxygen supply.
* Low Pressure Oxygen Audible Alarm.

NOTE:
Cylinders,Circle Absorber, & other items than the above mentioned specifications are supplied at extra cost.

Request for quote >> 
 
 
DESCO Anaesthesia Machine (Cat. No. D-AN 1015)

SPECIFICATION
1. Two Gases Rotameter Oxygen & Nitrous-Oxide
2. Oxygen Flowmeter range 100 cc/min. to 10 litres/min., Nitrous Oxide Flowmeter range 200cc /min. to 12      litres/min.
3. Standard Fresh Gas Outlet.
4. Change Over System Open Circuit to Close Circuit.
5. Emergency Flush Valve at front Panel connected to incoming O2 supply
6. Goldman type Halothane Vaporizer.
7. Parking space for two additional Vaporizers.
8. Non-return cum Pressure Relief Valve minimize risk of back flow of gases.
9. Blows off valve when pressure exceeds 200cm of water column fitted.
10. Provision to fit Ventilator.
11. Provision to fit Carbon Dioxide Absorber.
12. Extended platform at rear for two 'B' type cylinder.
13. Table top made of Stainless Steel.
14. Top Tray provided at eye lavel for keeping Monitoring Equipments.
15. Maggill's or Bains circuit.
16. Three spacious Drawer on smooth runner.
17. Four Castor Trolley with front two lockable Wheels.
18. Pin Index Yokes two for Oxygen and two for Nitrous Oxide.
19. High-efficiency Regulators for reliability two each for O2 & N2O.

SAFETY FEATURES
* N2O cut off in case failure of Oxygen supply.
* Low Pressure Oxygen Audible Alarm.

NOTE:
Cylinders,Circle Absorber, & other items than the above mentioned specifications are supplied at extra cost.

Request for quote >> 
 
 
DESCO ANAESTHESIA APPARATUS MAJOR (Cat. No. D-AN 1016)

SPECIFICATION
1. Long rotating bobbin flowmeter (230 mm) tube calibrated.
2. Oxygen flowmeter range 100cc/min. to 8 liters/min., Nitrous Oxide flowmeter range 200 cc/min.      to 12 liters/min.
3. Fresh gas outlet cum emergency oxygen unit located at a convenient position.
4. Plenum type ether vaporizer.
5. Goldman type halothene vaporizer.
6. Built-in space for one more vaporizer.
7. Non return cum pressure relief valve.
8. Provision to fit ventilator.
9. Provision to fit carbon dioxide absorber.
10. Provision to accommodate two Nos. 10 ltr. Cylinders at the back side.
11. Table top made of stainless steel.
12. Top tray at eye level to keep monitoring instrument.
13. Maggill's circuit or bains circuit.
14. Fitted with two large diameter gauges each for Oxygen and Nitrous Oxide.
15. Two gauges to show pipeline pressure one for O2 for N2O.
16. One spacious drawer on smooth runner.
17. Pin index Yokes two for Oxygen and two for Nitrous Oxide.
18. Change over system for open and close circuit.
19. Preset regulators for O2 and N2O two each.
20. Shelf for Ampule.

SAFETY FEATURES
* N2O CUT OFF IN CASE FAILURE OF OXYGEN SUPPLY.
* LOW PRESSURE OXYGEN AUDIBLE MECHANICAL ALARM.
* HYPOXICGAURD (ROTAMETER ENSURE PROTECTION
AGAINST SINGULAR FLOW OF N2O UNTIL A MINIMUM
FLOW OF 1.5 LITRE OXYGEN IS RELEASED.)

NOTE:
Cylinders,Circle Absorber, & other items than the above mentioned specifications are supplied at extra cost  

Request for quote >>
 
 
DESCO ANAESTHESIA APPARATUS MAJOR (Cat. No. D-AN 1017)

SPECIFICATION
1. Long rotating bobbin flowmeter (230 mm).
2. Plenum type ether Vaporizer.
3. Goldman type Halothene Vaporizer.
4. Non-return cum pressure relief valve.
5. 50 mm die Oxygen Guages.
6. 50 mm die Nitorious-oxide Guages.
7. Table top stainless steel.
8. Top tray for Monitoring Instruments.
9. Pin Indexed Yokes for Oxygen.
10. Pin Indexed Yokes for Nitorous-oxide.
11. Emergency Oxygen supply button.
12. Outlet.
13. Detachable capacious drawer.
14. Maggill's circuit.
15. Stainless/painted(Powered coated)frame.
16. N2O cut off system.
17. Preset Regulator for O2 & N2O.
18. Wheels with brake.

SAFETY FEATURES
* N2O cut off in case oxygen pressure falls below 10-15 Pnds.

Request for quote >>
 
 
Products Categories  
 
 Anaesthesia
 Autoclaves
 Baby Care Equipments
 Blood Bank
 Cold Chain
 Diagnostic Instruments  
 Hospital Furniture 
 Hospital Garments 
 Hospital Holloware 
 Laboratory Equipments 
 Medical Disposables  
 Microscopes & Projectors  
 Miscellaneous Products 
 Ophthalmic
 Orthopaedic Implants & Instruments
 Oxygen Cylinders
 Physiotherapy Equipments
 Rehabilitation Aids
 Shadowless Lights
 Suction Units
 Surgical Needles
 Surgical Rubber Goods
 Surgical Instruments
 Weighing Scale
 
 
Go To Top  
 
Copyright Deluxe Scientific Surgico Pvt. Ltd, India : 2011